SmartOnline Double-Conversion UPS - 2U, USB, DB9, 230V, 3kVA, 2.5kW, On-Line

Series: SMARTONLINE

Model: SUINT3000RTXL2U

  • High-performance system is ideal for critical voice, data, medical and industrial network applications
  • Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation
  • Economy mode is schedulable via PowerAlert UPS management software
  • Online and double-conversion mode
  • Corrects line voltage conditions as low as 120V and as high as 288V to within 2% of selected nominal voltage
Compare
Project List
Product Info
Tech Specs
Related Products
Documents
Accessories
3kVA/2500W online double-conversion UPS system for critical server, network and telecommunications equipment. 2U rack-mount form factor with an installed depth of only 66cm (26 inches). Expandable battery runtime with optional BP72V15-2U (limit 1) and BP72V28RT3U (multi-pack compatible) external battery packs. Full time sine wave 200/208/220/230/240V output with +/-2% voltage regulation. Uninterruptible power supply (UPS) actively converts raw incoming AC power to DC, then reconverts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 120V and overvoltages to 288V. Up to 97% efficiency in optional economy mode saves BTU heat output and energy costs. C20 inlet accepts a wide variety of optional cord sets. C19 and C13 output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces include USB port, DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency power off (EPO) interface. Integrated two bank PDU switching supports automated load shedding and remote-reboot of connected equipment. Multistage metered current monitoring and battery charge status LEDs. Mains power and voltage regulation LEDs. Audible alarm and self-test. Fault-tolerant auto-bypass mode. LED display panel easily rotates for better viewing in rack-mount or tower configurations. Includes 4 post rack-mount installation accessories. 2-9USTAND tower kit and 2POSTRMKITWM two post rack-mount and wall-mount hardware accessories available. Field replaceable, hot swappable internal batteries and external battery packs.
  • High-performance system is ideal for critical voice, data, medical and industrial network applications
  • Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation
  • Economy mode is schedulable via PowerAlert UPS management software
  • Online and double-conversion mode
  • Corrects line voltage conditions as low as 120V and as high as 288V to within 2% of selected nominal voltage
  • Standard internal battery set
  • Expandable battery runtime with optional BP72V15-2U and BP72V28RT-3U external battery packs
  • Compact rack-mount form factor
  • Ships with all mounting accessories for 4 post rack-mount installation
  • Optional 2POSTRMKITWM enables 2 post rack- or wall-mount installation
  • Optional 2-9USTAND accessory enables upright tower placement
  • Fault tolerant electronic bypass
  • Network interfaces support simultaneous communications via built-in USB, DB9 serial/contact-closure and SNMPWEBCARD slot
  • HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
  • Included PowerAlert UPS monitoring software
  • Built-in emergency power off (EPO) interface with cable
  • C20 inlet and included 10ft/3m C19 to C20 cable
  • C19 and C13 output receptacles
  • Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each bank has 4 C13 outlets)
  • Front panel LEDs offer current monitoring and battery charge level information
  • Network grade AC surge suppression
  • Field replaceable, hot swappable internal batteries and external battery packs
  • Suitable for distributed server rooms, network closets, small business networks and small business phone system
 
 