Tripp Lite - PDUMH30ATNET

2.9kW Single-Phase ATS / Switched PDU, LX Platform Interface, 120V Outlets (24 5-15/20R, 1 L5-30R) 2 L5-30P, 2 10ft Cords, 2U Rack-Mount, TAA

Model: PDUMH30ATNET

  • Single phase 30A 120V Auto Transfer Switch/ATS PDU
  • Enables redundant-power option for single-corded network devices
  • Separate primary and secondary inputs connect to any two compatible power sources
  • 2U horizontal rackmount, 2 L5-30P inputs, 24 5-15/20R and 1 L5-30R outlets
  • Individually switched outlets, network interface and 2 digit visual current meter
Compare
Project List
Product Info
Tech Specs
Related Products
Documents
Switched ATS/Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to primary and secondary power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Smart online series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
  • Single phase 30A 120V Auto Transfer Switch/ATS PDU
  • Enables redundant-power option for single-corded network devices
  • Separate primary and secondary inputs connect to any two compatible power sources
  • 2U horizontal rackmount, 2 L5-30P inputs, 24 5-15/20R and 1 L5-30R outlets
  • Individually switched outlets, network interface and 2 digit visual current meter
  • ATS circuits normally maintain output sourced from the primary input cable
  • ATS configurations enable hot-swap UPS protection when used with single UPS
  • Advanced ATS configurations utilize separate mains circuits
  • On-board ATS processor constantly evaluates power quality on both inputs
  • 3 to 6 millisecond transfer time between primary and secondary inputs
  • Compatible with optional ENVIROSENSE temperature monitor
  • Front panel LEDs confirm power availability on primary / secondary inputs and each output
 
 