High-mount outdoor weatherproof sensor with 94 detection zones.
Unique pyro-element provides multiple pattern detection and accurate discrimination function for spot temperature changes of moving objects. Drastically reduces false and missed alarms caused by severe outdoor environmental changes. Upper and lower area must be activated to generate an alarm condition. Summer night compensation, advanced temperature compensation, and vegetation sway analysis logic.
Ideal detection area setting – adjustable length/spot detection.
Registers movement in area covered: 13/18/30/40 ft and 85° wide
High-mount outdoor weatherproof sensor with 94 detection zones.
Unique pyro-element provides multiple pattern detection and accurate discrimination function for spot temperature changes of moving objects. Drastically reduces false and missed alarms caused by severe outdoor environmental changes. Upper and lower area must be activated to generate an alarm condition. Summer night compensation, advanced temperature compensation, and vegetation sway analysis logic.
Ideal detection area setting – adjustable length/spot detection.
Registers movement in area covered: 13/18/30/40 ft and 85° wide
LED indicators for operation and system status.
Unwanted detection areas can be eliminated using the included area masking seal.
Mounting height: 8.3 to 10 feet.
Tamper switch opens when cover is removed.
Screw terminal. Connect to digital input or RJ45 sensor ports on an ENVIROMUX system. To connect to the digital inputs, use a 22 AWG 2-wire cable. Connect the other end to the sensor screw terminal. To connect to the RJ45 inputs, use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal.
Current consumption: 35mA @ 12VDC.
Powered by E-2D/5D/16D.
Spec Sheet available - Yes
Operating Temperature (Maximum):
140 F
Operating Temperature (Minimum):
-4 F
Regulatory Compliance:
IP54 compliant
Maximum Cable Length:
520 ft (160 m) (22 AWG).
E-16D
- Large Enterprise Environment Monitoring System. Power: AC. Logging: 1,000 data log entries; 1,000 event log entries.
E-16DEL
- Large Enterprise Environment Monitoring System. Power: AC. Logging: 1,200,000 data log entries; 3,000 event log entries.
E-2D
- Small Enterprise Environment Monitoring System
E-5D
- Medium Enterprise Environment Monitoring System
E-5D-IND48VLT
- Industrial Medium Enterprise Environment Monitoring System, 48VDC Power
E-5D-INDLT
- Industrial Medium Enterprise Environment Monitoring System