Line input transformers provide the maximum possible Common Mode Rejection of unwanted signals. All models have a single Faraday shield and a 30dB magnetic shield can. Models are available in 1:1, 1:1.4, 1:2, 2:1 and 4:1 ratios.
Ideal passive Pro to Consumer level converter
Wide bandwidth -3dB at 0.5Hz and 180kHz
Recommended for levels up to +21dBu at 20Hz
High input impedance of 40kohm
High common-mode rejection of 120dB at 60Hz
Audio Transformer Type - Input Transformer
Audio Transformer Type - Line Transformer
Spec Sheet available - Yes
Operating Temperature (Maximum):
158 F
Operating Temperature (Minimum):
32 F
Maximum Bandwidth:
180 kHz (-3dB)
Impedance Ratio:
40k:2.4k
Input Impedance:
41.5 kohm (1kHz, +4dBu, test circuit 1)
Voltage Gain:
-12.9 dB (1kHz, +4dBu, test circuit 1)
Magnitude response, ref 1 kHz:
-0.04 (20Hz, +4dBu, test circuit 1, Rs=600ohm) and -0.03 (20kHz, +4dBu, test circuit 1, Rs=600ohm) dB
Deviation from linear phase (DLP):
+0.6/-0.1 degree (20Hz to 20kHz, +4dBu, test circuit 1, Rs=600ohm)
Distortion (THD):
<0.001 (1kHz, +4dBu, test circuit 1, Rs=600ohm) and 0.015 (20Hz, +4dBu, test circuit 1, Rs=600ohm) %
Maximum 20Hz input level:
+21 dBu (1% THD, test circuit 1, Rs=600ohm)
Common-mode rejection ratio (CMRR) 50ohm balanced source:
120 (60Hz, test circuit 2) and 85 (3kHz, test circuit 2) dB
Common-mode rejection ratio (CMRR) 600ohm unbalanced source:
90 (60Hz, test circuit 3) and 55 dB (3kHz, test circuit 3)
Output Impedance:
225 kohm (1kHz, test circuit 1, Rs=600ohm)
Primary DC resistances:
2.5 kohm (RED to BRN)
Secondary DC resistances:
92 kohm (YEL to ORG)
Capacitance at 1kHz:
120 (primary to shield and case) and 115 (secondary to shield and case) pF
Turns Ratio:
4.000:1
Breakdown Voltage:
250 Vrms (primary or secondary to shield and case, 60Hz, 1 minute test duration)