The CP-3200E is a keypad panel arranged to operate as an XY panel allowing control of any input or output, with up to four levels of breakaway. The CP-3200E is normally used as a master XY panel in engineering or MCR type applications where access to any input or output is required. The CP-3200E is suitable for any system from 16x4 and above. Advanced programming control enables the CP-3200E also to be configured to control five destinations without breakaway or a single destination with five levels of breakaway.
XY mode with four levels of breakaway
Five destination mode with a TAKE button for each destination but without breakaways
Single destination mode with five levels of breakaway
24 + 6 button keypad for source and destination names
High brightness vacuum fluorescent alphanumeric display with better viewing angles than LCD types
Source names can be up to seven characters long
Destination names can be up to eight characters long
In use displays for all levels plus preset
All buttons fully programmable for different functions such as LOCK
TAKE button optionally causes the source in use and preset displays to toggle
Optional NEXT and LAST buttons to scroll through the available sources and destinations
Camera joystick override on any eight inputs, with momentary or latching action
Supports Ethernet for connection to MAGNUM Router Control system
Systems Controlled - Other
Spec Sheet available - Yes
Operating Temperature (Maximum):
104 F
Operating Temperature (Minimum):
32 F
Rack Units (Height):
2
AC Voltage (Maximum):
240 Volts
AC Voltage (Minimum):
100 Volts
Active Power:
40 Watt
Current Draw:
3 Amps
DC Voltage:
12 Volts
Depth:
3.50 in
Height:
3.50 in
Width:
19 in
Product Weight:
4 lbs
Regulatory Compliance:
Complies with FCC Part 15 Class A regulations, Complies with EU EMC directive
Joystick:
8 Parallel contact closures, TTL levels (GPI). D9 male
Qlink:
75? coaxial connection for direct connection to routers. BNC, “T” adapter and termination required.
Ethernet:
Standard Ethernet interface for connection to MAGNUM Router Control system. RJ4
Fuse Rating:
250V, 1A, time delay
Safety: