ESE - ES-911E/GPS/NTP™

NENA-PSAP GPS Master Clock / TCG with NTP

Model: ES-911E/GPS/NTP™

  • Ethernet NTP port (10/100Base-T, RJ-45)
  • IRIG-B & IRIG-E outputs
  • RS-232C outputs (Broadcast & Query)
  • RS-485 Broadcast output
  • ESE Time Code output (TC90)
Compare
Project List
Product Info
Tech Specs
Related Products
Documents
The ES-911E/GPS/NTP is a GPS (Global Positioning System) Master Clock and Time Code Generator. The unit is specifically designed to meet the NENA (National Emergency Number Association) Standard NENA-04-002 for a PSAP (Public Safety Answering Point) Master Clock and is capable of Time Synchronizing all components of a PSAP. The unit displays six digits of time -- legally traceable to UTC (Universal Coordinated Time) as received via the internal 12-channel GPS receiver. Simultaneously the ES-911U/GPS/NTP generates several types of time code - IRIG-B and IRIG-E and ESE and RS232C (both Broadcast and Query ports provided) and a 1PPS signal. These outputs allow the ES-911U/GPS to synchronize and easily interface with equipment such as CAD and ANI / ALI Controllers and Voice Recorders and Radio Consoles that meet NENA Standards. The ES-911U/GPS/NTP can also synchronize computers and other digital / analog clock systems. The unit also features an Ethernet NTP port for network time synchronization. Included with the ES-911U/GPS/NTP is an indoor / outdoor antenna that is connected to the unit via the provided 16 ft. cable. If additional cable is required -- low-loss cable or an in-line amplifier (LA-12F or LA-12FN for low-loss cable) or for extra long cable runs where more than one in-line amplifier is used -- an Antenna Power Supply (ES-AB1) may be required. Consult the ESE factory for more information. Software is also supplied with the ES-911U/GPS/NTP permitting the user to continuously update a computers DOS or Windows clock to the GPS time available on the Broadcast RS-232C output.
  • Ethernet NTP port (10/100Base-T, RJ-45)
  • IRIG-B & IRIG-E outputs
  • RS-232C outputs (Broadcast & Query)
  • RS-485 Broadcast output
  • ESE Time Code output (TC90)
  • 1 PPS output
  • Loss of Power & Loss of Time Sync relay outputs
  • Loss of GPS Signal output
  • IRIG Codes are switchable between Modulated and TTL
  • Auto Daylight Saving correction (may be disabled via internal switch)
  • Time Zone offset
  • Internal 60 minute battery back-up (4 hours display off)
  • "Time Sync", "GPS Lock" & NTP port status indicators
  • 6-Digit, .56" LED display
  • Product Options:
  • Ant---GPS Antenna: High Performance GPS Antenna for harsh RF Environments.
  • HR---Relay Contact Closure: A contact closure occurs at the top of each Hour. Hour and 1/2 Hour closure may be ordered on some products. Relay contacts are rated at 10-Watts maximum load, 500mA maximum switching current.
  • J---220 VAC/50 Hz Operation: The unit is configured to operate from 220 VAC line voltage. 117 VAC 50/60 Hz is standard.
  • K---provides a 10 MHz output and a 1 KHz output.
  • Display switchable between 12 & 24 Hour format
  • +/- 10 Nanosecond accuracy
  • Legally Traceable to UTC (Universal Coordinated Time)
  • Meets or exceeds NENA-04-002 Master Clock specifications
  • Indoor/Outdoor antenna with 16' Cable
  • Rugged Rack Mount enclosure
  • UL Approved power supply
  • Simple operation & installation
  • Digital, Video & Analog slave clocks available
 
 